15kV
|
30kV
|
Accuracy
of Voltage Setting |
±5% or ±0.2kV
|
Display
Resolution |
0.01kV
|
0.1kV
|
Range
of Coating Thickness |
0 - 3.75mm (approximate)
0
- 150mils (approximate)
|
0 - 7.5mm (approximate)
0
- 300mils (approximate)
|
Voltage
Output |
0.5 - 15kV in
100V steps
|
0.5 - 30kV in
100V steps
|
Alarms |
Audio &
Visual
|
Power
Supply |
NiMH 12V internal
rechargeable battery
|
Battery
Life (approximate) |
10/12 hours
continuous use, the optional external battery pack can increase
this to 20/24 hours of continuous use
|
Unit
Dimensions |
200 x 170 x
70mm (6 x 7 x 3")
|
Product
Weight (including case and probe) |
2.8kg (6lb 3oz)
|
Packing
List |
Elcometer
236 DC Holiday Detector, probe handle and lead, band brush
probe, 2m (79") and 10m (394") signal return/earth
leads, battery charger, carry case, transit case and operating
instructions
|